LED Error Codes
Status LED STM
e STM drive+motor includes red and green LEDs to indicate status. When the motor is enabled, the green LED
ashes slowly. When the green LED is solid, the motor is disabled. Conditions and errors are indicated by combina-
tions of red and green “ashes” as follows:
Code Condition
solid green no alarm, motor disabled
flashing green(slow) no alarm, motor enabled
1 red, 1 green motor stall (optional encoder only)*
1 red, 2 green
move attempted while drive disabled
2 red, 1 green
ccw limit
2 red, 2 green cw limit
3 red, 1 green drive overheating*
3 red, 2 green internal voltage out of range*
4 red, 1 green power supply overvoltage*
4 red, 2 green power supply undervoltage
5 red, 1 green over current / short circuit*
6 red, 1 green open motor winding*
7 red, 1 green serial communication error
flashing green(fast)
Q Program running
*ese errors are faults and will disable the motor. ey also cause the output to activate if it is so congured.