e Digital Output
e STM17 drives feature one optically isolated digital output. is output can be set to automatically con-
trol a motor brake, to signal a fault condition, to indicate when the motor is moving or to provide an output
frequency proportional to motor speed (tach signal). e output can also be turned on and o by program
instructions like Set Output. e output can be used to drive LEDs, relays and the inputs of other electronic
devices like PLCs and counters. e “OUT+” (collector) and “OUT-” (emier) terminals of the transistor are
available at the connector. is allows you to congure the output for current sourcing or sinking.
Note: If current is owing into or out of an output, the logic state of that output is low or closed. If no current is
owing, or the output is not connected, the logic state is high or open.
Do not connect the output to more than 30VDC.
e current through the output terminal must not exceed 40mA.
Example connection diagrams:
Connecting a Sinking Output
Connecting a Sourcing Output
Driving a Relay
STM17
5-24 VDC
Power Supply
+
Load
OUT-
OUT+
5-24 VDC
Power Supply
+
OUT-
OUT+
STM17
Load
STM17
1N4935 suppression diode
5-24 VDC
Power Supply
+
relay
OUT-
OUT+
22