21
Rev. A
920-0085
TSM17C Hardware Manual
4 Troubleshooting
LED Error Codes
The TSM17C uses red and green LEDs to indicate status. When the motor is enabled, the green
LED ashes slowly. When the green LED is solid, the motor is disabled. Errors are indicated by
combinations of red and green ashes as shown below. This feature can be disabled for certain
warnings but not for alarms. See software manual for information on how to do this and which
warnings may be masked.
Code Error
Solid green no alarm,motor disabled
Flashing green no alarm,motor enabled
1 red,1 green
motor stall (optional encoder only)
2 red,1 green
ccw limit
2 red,2 green
cw limit
3 red,1 green drive overheating
3 red,2 green internal voltage out of range
3 red,3 green
blank Q segment
4 red,1 green power supply overvoltage or excess regen
4 red,2 green power supply undervoltage
4 red,3 green
ash memory backup error
5 red,1 green Over current/short circuit
6 red,1 green Open motor winding
6 red,2 green
bad encoder signal (optional encoder only)
7 red,1 green
communication error
7 red,2 green
ash memory error
Komentáře k této Příručce