Applied-motion STR2 Uživatelský manuál Strana 12

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 11
12
STR2 Hardware Manual
920-0059B
1/30/2014
Regeneration
If you plan to use a regulated power supply you may encounter a problem with regeneration.
If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is
transferred back to the power supply. is can trip the overvoltage protection of a switching
power supply, causing it to shut down. Unregulated power supplies are beer because they
generally do not have overvoltage protection and have large capacitors for storing energy
coming back from the drive. ey are also less expensive. See previous section on
Connecting
the Power Supply
for details on the RC-050 regeneration clamp.
System Wiring Recommendations
1. Separate the DC power supply cable by at least 2” from the small signal input cable and the
encoder feedback cable.
2. A shielded cable for the DC power supply connections will result in a quieter system.
Ground the shield at the power supply.
3. A shielded cable is recommended for the small signal connections. Ground the shield at
the signal source.